{"audience":"S/4HANA conversion project teams, logistics solution architects, warehouse process owners and project managers.","authorization_objects":[{"note":"Display authorization by warehouse number and storage type","object":"L_LGNUM"}],"components":[],"countries":[],"effort_days_max":8,"effort_days_min":5,"effort_size":"M","faq":[{"a":"Yes. It runs in ECC before every mock conversion and before the go-live cutover. Clearing open work and negative quants shortens the cutover weekend, and the bin and stock volume to move to EWM is planned from here.","q":"Is the report run before moving to S/4HANA?"},{"a":"Yes. Clearing open work is needed for both targets. The number of storage-unit-managed types and the bin volume also help decide whether simple stock room management is enough.","q":"Is it useful if Stock Room Management is chosen instead of EWM?"},{"a":"No. The report shows only warehouse structure and document counts; it contains no material, customer or personal data, so it can be shared freely with project management and external consultants.","q":"Do the numbers contain personal or customer data?"}],"features":[{"code":"alv","label":"ALV list (sort, filter, subtotals)","note":""},{"code":"layout","label":"User-specific layout variants","note":""},{"code":"drilldown","label":"Double-click drill-down to the document","note":"Double-clicking open transfer orders opens LT22, open transfer requirements LB10, negative quants LX02."},{"code":"excel","label":"Export to Excel","note":"The result can be exported to Excel to compare mock conversions."},{"code":"background","label":"Runs as a background job","note":""}],"functions":[],"gap":"LE-WM is part of the compatibility scope in S/4HANA, and the target is usually EWM or Stock Room Management. Standard LX03, LT22 and LX09 show each topic separately per warehouse; no list collects all volume and open-work indicators needed for migration planning in one table per warehouse number. Project teams gather these numbers by hand before every mock conversion.","id":"wm-ewm-migration-readiness","industries":[],"input_columns":[],"kind":"report","language":"en","lastmod":"2026-11-17","logic":"1. The selected warehouse numbers are read from T300 with descriptions in the logon language from T300T; the number of assigned plant and storage location combinations comes from T320.\n2. The number of storage types is taken from T301, and the number of storage types with storage unit management (LENVW) from T331.\n3. Total bins and occupied bins (KZLER blank) are counted from LAGP; the number of quants and of negative quants with available quantity below zero from LQUA.\n4. Open work: unconfirmed transfer orders (LTAK-KQUIT blank), incomplete transfer requirements (LTBK-STATU), unprocessed posting change notices (LUBU-STATU) and incomplete inventory documents (LINK-ISTAT) are counted.\n5. The number of storage units is taken from LEIN.\n6. A readiness status is set per warehouse: \"Clean-up needed\" when negative quants or open work exist, otherwise \"Ready\"; the thresholds can be set on the selection screen.","module":"WM","object_type":"alv_report","output_columns":[{"calculated":false,"formula":"","label":"Warehouse","source_field":"LGNUM","source_table":"T300"},{"calculated":false,"formula":"","label":"Description","source_field":"LNUMT","source_table":"T300T"},{"calculated":true,"formula":"Number of T320 records assigned to the warehouse","label":"Plant/storage loc.","source_field":null,"source_table":null},{"calculated":true,"formula":"Number of T301 records","label":"Storage types","source_field":null,"source_table":null},{"calculated":true,"formula":"Number of storage types with T331-LENVW set","label":"SU-managed types","source_field":null,"source_table":null},{"calculated":true,"formula":"Number of LAGP records","label":"Bins","source_field":null,"source_table":null},{"calculated":true,"formula":"Number of bins with LAGP-KZLER blank","label":"Occupied bins","source_field":null,"source_table":null},{"calculated":true,"formula":"Number of LQUA records","label":"Quants","source_field":null,"source_table":null},{"calculated":true,"formula":"Number of quants with LQUA-VERME \u003c 0","label":"Negative quants","source_field":null,"source_table":null},{"calculated":true,"formula":"Number of transfer orders with LTAK-KQUIT blank","label":"Open TOs","source_field":null,"source_table":null},{"calculated":true,"formula":"Number of requirements whose LTBK-STATU is not completed","label":"Open TRs","source_field":null,"source_table":null},{"calculated":true,"formula":"Number of notices whose LUBU-STATU is not completed","label":"Open PCNs","source_field":null,"source_table":null},{"calculated":true,"formula":"Number of documents whose LINK-ISTAT is not completed","label":"Open inventory docs","source_field":null,"source_table":null},{"calculated":true,"formula":"Number of LEIN records","label":"Storage units","source_field":null,"source_table":null},{"calculated":true,"formula":"Clean-up needed when negative quants \u003e 0 or open-work thresholds are exceeded, otherwise ready","label":"Readiness","source_field":null,"source_table":null}],"parameters":[{"example":"100","kind":"select_option","label":"Warehouse number","name":"S_LGNUM","ref_field":"T300-LGNUM","required":true},{"example":"1000","kind":"select_option","label":"Plant (via the T320 assignment)","name":"S_WERKS","ref_field":"T320-WERKS","required":false},{"example":"0","kind":"parameter","label":"Maximum open transfer orders allowed","name":"P_OPENTO","ref_field":"","required":false},{"example":"0","kind":"parameter","label":"Maximum open transfer requirements allowed","name":"P_OPENTR","ref_field":"","required":false},{"example":"","kind":"checkbox","label":"Detail lines per storage type","name":"P_DETAIL","ref_field":"","required":false}],"part_of":[],"performance":"Do all counting on the database with COUNT(*) and GROUP BY per warehouse number; do not read any table line by line. The report then finishes in minutes even in warehouses with millions of quants and can be re-run before every mock conversion.","process":"INV","quote_url":"https://nekuhub.com/en/request-a-quote/?report=wm-ewm-migration-readiness","related":["wm-open-posting-change-notices-aging","wm-open-transfer-requirements-aging","wm-unconfirmed-transfer-orders-aging"],"releases":[],"source":"custom","standard_alternatives":[{"note":"Lists open transfer orders by storage type; does not collect the other migration indicators.","tcode":"LT22"},{"note":"Gives an overview of transfer requirements; does not show bin, quant and inventory volume.","tcode":"LX09"}],"summary":"A check report that summarizes, before an S/4HANA conversion, the structure and open workload of every warehouse number on one line: storage types, bins, occupied bins, quants, negative quants, open transfer orders, open transfer requirements, unprocessed posting change notices, open inventory documents and storage units. It shows what must be cleaned up before the cutover and the master data volume to move to EWM.","tables":[{"access":"read","join_on":"","role":"Warehouse numbers (driving table)","table":"T300","variant":"both"},{"access":"read","join_on":"T300T-LGNUM = T300-LGNUM AND T300T-SPRAS = SY-LANGU","role":"Warehouse number description","table":"T300T","variant":"both"},{"access":"read","join_on":"T320-LGNUM = T300-LGNUM","role":"Assigned plant and storage location combinations","table":"T320","variant":"both"},{"access":"read","join_on":"T301-LGNUM = T300-LGNUM","role":"Storage types","table":"T301","variant":"both"},{"access":"read","join_on":"T331-LGNUM = T300-LGNUM","role":"Storage unit management setting","table":"T331","variant":"both"},{"access":"read","join_on":"LAGP-LGNUM = T300-LGNUM","role":"Number of bins and occupancy","table":"LAGP","variant":"both"},{"access":"read","join_on":"LQUA-LGNUM = T300-LGNUM","role":"Number of quants and negative quants","table":"LQUA","variant":"both"},{"access":"read","join_on":"LTAK-LGNUM = T300-LGNUM","role":"Unconfirmed transfer orders","table":"LTAK","variant":"both"},{"access":"read","join_on":"LTBK-LGNUM = T300-LGNUM","role":"Open transfer requirements","table":"LTBK","variant":"both"},{"access":"read","join_on":"LUBU-LGNUM = T300-LGNUM","role":"Unprocessed posting change notices","table":"LUBU","variant":"both"},{"access":"read","join_on":"LINK-LGNUM = T300-LGNUM","role":"Incomplete inventory documents","table":"LINK","variant":"both"},{"access":"read","join_on":"LEIN-LGNUM = T300-LGNUM","role":"Number of storage units","table":"LEIN","variant":"both"}],"title":"LE-WM to EWM Migration Readiness Check Report (S/4HANA)","url":"https://nekuhub.com/en/reports/wm-to-ewm-migration-readiness-check-report/","vendor_id":"nekudos"}